Transferrin ELISA Kit

TF Reaktivität: Human Colorimetric Sandwich ELISA 937.50-60000 pg/mL Cell Culture Supernatant, Plasma, Serum
Produktnummer ABIN3198488
  • Target Alle Transferrin (TF) ELISA Kits anzeigen
    Transferrin (TF)
    Reaktivität
    • 7
    • 5
    • 4
    • 3
    • 3
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Human
    Nachweismethode
    Colorimetric
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    937.50-60000 pg/mL
    Untere Nachweisgrenze
    937.50 pg/mL
    Applikation
    ELISA
    Verwendungszweck
    This assay employs the quantitative sandwich enzyme immunoassay technique for quantitative detection.
    Proben
    Cell Culture Supernatant, Plasma, Serum
    Analytische Methode
    Quantitative
    Spezifität
    Transferrin / TF, Human
    Sensitivität
    2.82 pg/mL
    Bestandteile
    Plate, Standard, Diluent
    Benötigtes Material
    Microplate reader capable of measuring absorbance at 450 nm, with correction wavelength set at 570 nm or 630 nm.
    Pipettes and pipette tips.
    50 μL to 300 μL adjustable multichannel micropipette with disposable tips.
    Multichannel micropipette reservoir.
    Beakers, flasks, cylinders necessary for preparation of reagents.
    Deionized or distilled water.
    Polypropylene test tubes for dilution.
    Featured
    Zu unserem meistverkauften TF ELISA Kit
    Top Product
    Discover our top product TF ELISA Kit
  • Probenmenge
    100 μL
    Testdauer
    3 - 4 h
    Plattentyp
    Pre-coated
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Buffer
    Buffer contains: 0.02 % sodium azide
    Konservierungsmittel
    Sodium azide
    Vorsichtsmaßnahmen
    This product contains Sodium azide: a POISONOUS AND HAZARDOUS SUBSTANCE which should be handled by trained staff only.
    Handhabung
    Intended for research use only and are not for use in diagnostic or therapeutic procedures.
    Treat all chemicals with caution because they can be potentially hazardous.
    It is recommended that this product is handled only by persons who have been trained in laboratory techniques and in accordance with the principles of good laboratory practice. Wear personal protection equipment such as laboratory coat, safety glasses and gloves.
    Avoid direct contact with skin or eyes. Wash immediately with water in the case of contact with skin or eyes. Avoid contact of skin or mucous membranes with kit reagents or specimens. See material safety data sheet(s) for specific advice.
    Pure water or deionized water must be used for reagent preparation.
    The Stop Solution provided with this kit is an acid solution. Wear personal protection equipment with caution.
    Do not expose kit reagents to strong light during storage and incubation.
    Rubber or disposable latex gloves should be worn while handling kit reagents or specimens.
    Avoid contact of substrate solution with oxidizing agents and metal.
    Avoid splashing or generation of aerosols.
    Use disposable pipette tips and/or pipettes to avoid microbial or cross-contamination of reagents or specimens which may invalidate the test.
    Use clean, dedicated reagent trays for dispensing the conjugate and substrate reagent.
    Exposure to acid inactivates the HRP and antibody conjugate.
    Substrate solution must be warmed to room temperature prior to use.
    Decontaminate and dispose specimens and all potentially contaminated materials as they could contain infectious agents. The preferred method of decontamination is autoclaving for a minimum of 1 hour at 121.5 °C.
    Liquid wastes not containing acid and neutralized waste may be mixed with sodium hypochlorite in volumes such that the final mixture contains 1.0 % sodium hypochlorite. Allow 30 minutes for effective decontamination. Liquid waste containing acid must be neutralized prior to the addition of sodium hypochlorite.
    All reagents including microplate, samples, standards and working solution should be warmed to room temperature before use.
    To obtain accurate results, using adhesive film to seal the plate during incubation is suggested.
    It is recommended that all samples and standards be assayed in duplicate.
    Avoid foaming when mixing or reconstituting solutions containing protein.
    To avoid cross-contamination, use separate reservoirs for each reagent and change pipette tips between each standard, sample and reagent.
    When using an automated plate washer, adding a 30 seconds soak period before washing step and/or rotating the plate between wash steps may improve assay precision.
    When pipetting reagents, maintain a consistent order of addition from well-to-well.
    Keep Substrate solution protected from direct strong light. Substrate Solution should turn to gradations of blue after a proper color development.
    Read absorbance within 30 minutes after adding stop solution.
    Take care not to scratch the inner surface of the microwells.
    Lagerung
    4 °C
    Informationen zur Lagerung
    Store kit reagents between 2 and 8 °C. Immediately after use remaining reagents should be returned to cold storage (2 to 8 °C).
    Expiry of the kit and reagents is stated on labels. Expiration date of the kit components can only be guaranteed if the components are stored properly, and if, in case of repeated use of one component, this reagent is not contaminated by the first handling.
    Unopened Kit: Store at 2 - 8 °C (See expiration date on the label).
    Opened/Reconstituted Reagents: Up to 1 month at 2 - 8 °C.
    Reconstituted Standard: Up to 1 month at ≤ -20 °C in a manual defrost freezer. Avoid repeated freeze-thaw cycles.
    Microplate Wells: Up to 1 month at 2 - 8 °C. Return unused strips to the foil pouch containing the desiccant pack, reseal along entire edge to maintain plate integrity. Provided this is within the expiration date of the kit
  • Target Alle Transferrin (TF) ELISA Kits anzeigen
    Transferrin (TF)
    Andere Bezeichnung
    Transferrin / TF (TF Produkte)
    Synonyme
    ltf ELISA Kit, pro1557 ELISA Kit, pro2086 ELISA Kit, mgc107777 ELISA Kit, LOC692564 ELISA Kit, TF ELISA Kit, LOC100144362 ELISA Kit, tf ELISA Kit, LTF ELISA Kit, TFEW ELISA Kit, conalbumin ELISA Kit, tf-b ELISA Kit, MGC64306 ELISA Kit, PRO1557 ELISA Kit, PRO2086 ELISA Kit, TFQTL1 ELISA Kit, AI266983 ELISA Kit, Cd176 ELISA Kit, HP ELISA Kit, Tf ELISA Kit, Tfn ELISA Kit, hpx ELISA Kit, Trf ELISA Kit, cb285 ELISA Kit, gavi ELISA Kit, id:ibd3238 ELISA Kit, id:ibd3525 ELISA Kit, sb:cb285 ELISA Kit, wu:fb57g06 ELISA Kit, wu:fb62h02 ELISA Kit, wu:fb63h10 ELISA Kit, wu:fb64h10 ELISA Kit, zgc:112154 ELISA Kit, 143958_at ELISA Kit, CG6186 ELISA Kit, Dmel\\CG6186 ELISA Kit, TSF1 ELISA Kit, anon-EST:Posey265 ELISA Kit, tsf1 ELISA Kit, Pro-TRH ELISA Kit, IL-5 ELISA Kit, STF I ELISA Kit, TRF1 ELISA Kit, sTF1 ELISA Kit, sTf ELISA Kit, tf1 ELISA Kit, transferrin ELISA Kit, serotransferrin ELISA Kit, transferrin (ovotransferrin) ELISA Kit, transferrin L homeolog ELISA Kit, melanotransferrin ELISA Kit, transferrin-a ELISA Kit, Transferrin 1 ELISA Kit, thyrotropin releasing hormone ELISA Kit, interleukin 5 ELISA Kit, TF ELISA Kit, LOC477072 ELISA Kit, tf ELISA Kit, Tf ELISA Kit, LOC100144362 ELISA Kit, tf.L ELISA Kit, LOC5575625 ELISA Kit, Trf ELISA Kit, tfa ELISA Kit, Tsf1 ELISA Kit, TRH ELISA Kit, IL5 ELISA Kit, LOC101085148 ELISA Kit, LOC100726872 ELISA Kit, trf ELISA Kit
    Hintergrund
    Transferrin (TF) is a secreted protein which belongs to the transferrin family. It is expressed by the liver and secreted in plasma. TF has a molecular weight of around 80 KDa and contains two specific high-affinity Fe (III) binding sites.
    Gen-ID
    7018
    NCBI Accession
    NM_001063
    UniProt
    P02787
    Pathways
    Transition Metal Ion Homeostasis