S100B ELISA Kit

S100B Reaktivität: Ratte Colorimetric Sandwich ELISA 31.2 pg/mL - 2000 pg/mL Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
Produktnummer ABIN3163685
  • Target Alle S100B ELISA Kits anzeigen
    S100B (S100 Calcium Binding Protein B (S100B))
    Reaktivität
    • 6
    • 3
    • 3
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Ratte
    Nachweismethode
    Colorimetric
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    31.2 pg/mL - 2000 pg/mL
    Untere Nachweisgrenze
    31.2 pg/mL
    Applikation
    ELISA
    Verwendungszweck
    The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of S100B in Serum,Plasma,Tissue Homogenate,Biological Fluids
    Proben
    Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
    Analytische Methode
    Quantitative
    Spezifität

    This assay has high sensitivity and excellent specificity for detection of S100 Calcium Binding Protein B (S100B).
    No significant cross-reactivity or interference between S100 Calcium Binding Protein B (S100B) and analogues was observed.

    Kreuzreaktivität (Details)
    No significant cross-reactivity or interference between S100 Calcium Binding Protein B (S100B) and analogues was observed.
    Sensitivität
    13.4 pg/mL
    Bestandteile
    • Pre-coated, ready to use 96-well strip plate, flat buttom
    • Plate sealer for 96 wells
    • Reference Standard
    • Standard Diluent
    • Detection Reagent A
    • Detection Reagent B
    • Assay Diluent A
    • Assay Diluent B
    • Reagent Diluent (if Detection Reagent is lyophilized)
    • TMB Substrate
    • Stop Solution
    • Wash Buffer (30 x concentrate)
    • Instruction manual
    Featured
    Zu unserem meistverkauften S100B ELISA Kit
    Top Product
    Discover our top product S100B ELISA Kit
  • Applikationshinweise
    • Limited by the current condition and scientific technology, we cannot completely conduct the comprehensive identification and analysis on the raw material provided by suppliers. So there might be some qualitative and technical risks to use the kit.
    • The final experimental results will be closely related to validity of the products, operation skills of the end users and the experimental environments. Please make sure that sufficient samples are available.
    • Kits from different batches may be a little different in detection range, sensitivity and color developing time.
    • Do not mix or substitute reagents from one kit lot to another. Use only the reagents supplied by manufacturer.
    • Protect all reagents from strong light during storage and incubation. All the bottle caps of reagents should be covered tightly to prevent the evaporation and contamination of microorganism.
    • There may be some foggy substance in the wells when the plate is opened at the first time. It will not have any effect on the final assay results. Do not remove microtiter plate from the storage bag until needed.
    • Wrong operations during the reagents preparation and loading, as well as incorrect parameter setting for the plate reader may lead to incorrect results. A microplate plate reader with a bandwidth of 10nm or less and an optical density range of 0-3 O.D. or greater at 450 ± 10nm wavelength is acceptable for use in absorbance measurement. Please read the instruction carefully and adjust the instrument prior to the experiment.
    • Even the same operator might get different results in two separate experiments. In order to get better reproducible results, the operation of every step in the assay should be controlled. Furthermore, a preliminary experiment before assay for each batch is recommended.
    • Each kit has been strictly passed Q.C test. However, results from end users might be inconsistent with our in-house data due to some unexpected transportation conditions or different lab equipments. Intra-assay variance among kits from different batches might arise from above factors, too.
    • Kits from different manufacturers for the same item might produce different results, since we have not compared our products with other manufacturers.
    Kommentare

    Information on standard material:
    The standard might be recombinant protein or natural protein, that will depend on the specific kit. Moreover, the expression system is E.coli or yeast or mammal cell. There is 0.05% proclin 300 in the standard as preservative.

    Information on reagents:
    The stop solution used in the kit is sulfuric acid with concentration of 1 mol/L. And the wash solution is TBS. The standard diluent contains 0.02 % sodium azide, assay diluent A and assay diluent B contain 0.01% sodium azide. Some kits can contain is BSA in them.

    Information on antibodies:
    The provided antibodies and their host vary in different kits.

    Probenmenge
    100 μL
    Testdauer
    3 h
    Plattentyp
    Pre-coated
    Protokoll
    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to S100 Calcium Binding Protein B (S100B). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to S100 Calcium Binding Protein B (S100B). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain S100 Calcium Binding Protein B (S100B), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of S100 Calcium Binding Protein B (S100B) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
    Aufbereitung der Reagenzien
    1. Bring all kit components and samples to room temperature (18-25 °C) before use. If the kit will not be used up in one time, please only take out strips and reagents for present experiment, and leave the remaining strips and reagents in required condition.
    2. Standard - Reconstitute the Standard with 1.0mL of Standard Diluent, kept for 10 minutes at room temperature, shake gently (not to foam). The concentration of the standard in the stock solution is 4,000pg/mL. First dilute the stock solution to 2,000 pg/mL and the diluted standard serves as the highest standard (2,000pg/mL). Then prepare 7 tubes containing 0.5mL Standard Diluent and use the diluted standard to produce a double dilution series. Mix each tube thoroughly before the next transfer. Set up 7 points of diluted standard such as 2,000pg/mL, 1,000pg/mL, 500pg/mL,250pg/mL, 125pg/mL, 62.5pg/mL, 31.2pg/mL, and the last tube with Standard Diluent is the blank as 0pg/mL.
    3. Detection Reagent A and Detection Reagent B - If lyophilized reconstitute the Detection Reagent A with 150μL of Reagent Diluent, keep for 10 minutes at room temperature, shake gently (not to foam). Briefly spin or centrifuge the stock Detection A and Detection B before use. Dilute them to the working concentration 100-fold with Assay Diluent A and B, respectively.
    4. Wash Solution - Dilute 20 mL of Wash Solution concentrate (30x) with 580 mL of deionized or distilled water to prepare 600 mL of Wash Solution (1x).
    5. TMB substrate - Aspirate the needed dosage of the solution with sterilized tips and do not dump the residual solution into the vial again.

    Note:

    1. Making serial dilution in the wells directly is not permitted.
    2. Prepare standards within 15 minutes before assay. Please do not dissolve the reagents at 37 °C directly.
    3. Please carefully reconstitute Standards or working Detection Reagent A and B according to the instruction, and avoid foaming and mix gently until the crystals are completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10μL for one pipetting.
    4. The reconstituted Standards, Detection Reagent A and Detection Reagent B can be used only once.
    5. If crystals have formed in the Wash Solution concentrate (30x), warm to room temperature and mix gently until the crystals are completely dissolved.
    6. Contaminated water or container for reagent preparation will influence the detection result.
    Testpräzision

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level S100 Calcium Binding Protein B (S100B) were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level S100 Calcium Binding Protein B (S100B) were tested on 3 different plates, 8 replicates in each plate.
    CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Vorsichtsmaßnahmen
    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
    Handhabung
    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition.
    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
    Lagerung
    4 °C/-20 °C
    Informationen zur Lagerung
    • For unopened kit: All the reagents should be kept according to the labels on vials. The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20°C upon receipt while the others should be at 4°C.
    • For opened kit: When the kit is opened, the remaining reagents still need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and reseal along entire edge of zip-seal.
      Note: It is highly recommended to use the remaining reagents within 1 month provided this is within the expiration date of the kit.
    • For ELISA kit, 1 day storage at 37°C can be considered as 2 months at 4°C, which means 3 days at 37°C equaling 6 months at 4°C.
    Haltbarkeit
    6 months
  • Weiss, Dhir, Collett, Reola, Kaplan, Minimo, Omert, Leung: "Effect of complement C1-esterase inhibitor on brain edema and inflammation after mild traumatic brain injury in an animal model." in: Clinical and experimental emergency medicine, Vol. 7, Issue 2, pp. 87-94, (2020) (PubMed).

    Ma, Zhao, Zhang, Chen: "Intra-arterial human urinary kallidinogenase alleviates brain injury in rats with permanent middle cerebral artery occlusion through PI3K/AKT/FoxO1 signaling pathway." in: Brain research, Vol. 1687, pp. 129-136, (2019) (PubMed).

    Ma, Wang, Fan, Zhang, Luo, Huang, Zhang, Li, Zhao, Li: "Protective Effects of Cornel Iridoid Glycoside in Rats After Traumatic Brain Injury." in: Neurochemical research, Vol. 43, Issue 4, pp. 959-971, (2018) (PubMed).

    Chen, Sun, Dong, Zhang, Zhou, Yu, Diao, Guo, Tian et al.: "Activated Α7nachr Improves Postoperative Cognitive Dysfunction and Intestinal Injury Induced by Cardiopulmonary Bypass in Rats: Inhibition of the Proinflammatory Response Through the Th17 Immune ..." in: Cellular physiology and biochemistry : international journal of experimental cellular physiology, biochemistry, and pharmacology, Vol. 46, Issue 3, pp. 1175-1188, (2018) (PubMed).

    Sedaghat, Taab, Kiasalari, Afshin-Majd, Baluchnejadmojarad, Roghani: "Berberine ameliorates intrahippocampal kainate-induced status epilepticus and consequent epileptogenic process in the rat: Underlying mechanisms." in: Biomedicine & pharmacotherapy, Vol. 87, pp. 200-208, (2017) (PubMed).

    Chen, Wang, Diao, Dong, Sun, Liu, Wu: "Hydrogen-Rich Saline Attenuates Brain Injury Induced by Cardiopulmonary Bypass and Inhibits Microvascular Endothelial Cell Apoptosis Via the PI3K/Akt/GSK3β Signaling Pathway in Rats." in: Cellular physiology and biochemistry : international journal of experimental cellular physiology, biochemistry, and pharmacology, Vol. 43, Issue 4, pp. 1634-1647, (2017) (PubMed).

    Tamaoki, Suzuki, Okada, Fukui, Isobe, Saito: "Development of an experimental rat model of hyperammonemic encephalopathy and evaluation of the effects of rifaximin." in: European journal of pharmacology, Vol. 779, pp. 168-76, (2016) (PubMed).

    Ekiz, Özdemir-Kumral, Erşahin, Tuğtepe, Öğünç, Akakın, Kıran, Özsavcı, Biber, Hakan, Yeğen, Şener, Toklu: "Functional and structural changes of the urinary bladder following spinal cord injury; treatment with alpha lipoic acid." in: Neurourology and urodynamics, Vol. 36, Issue 4, pp. 1061-1068, (2016) (PubMed).

    Ren, Yu, Wu, Liao, Tang, Zhan, Ou: "The experiment research of neuroprotection of hypoperfusion postconditioning on cerebral ischemia." in: The Journal of craniofacial surgery, Vol. 25, Issue 4, pp. e392-7, (2014) (PubMed).

    Er?ahin, Özdemir, Özsavc?, Akak?n, Ye?en, Reiter, Sener: "Melatonin treatment protects against spinal cord injury induced functional and biochemical changes in rat urinary bladder." in: Journal of pineal research, Vol. 52, Issue 3, pp. 340-8, (2012) (PubMed).

    Yang, Li, Ge, Mi, Wang, Sun: "Protective effects of naloxone in two-hit seizure model." in: Epilepsia, Vol. 51, Issue 3, pp. 344-53, (2010) (PubMed).

    Hariri, Moallem, Mahmoudi, Memar, Hosseinzadeh: "Sub-acute effects of diazinon on biochemical indices and specific biomarkers in rats: protective effects of crocin and safranal." in: Food and chemical toxicology : an international journal published for the British Industrial Biological Research Association, Vol. 48, Issue 10, pp. 2803-8, (2010) (PubMed).

    Er?ahin, Toklu, Erzik, Cetinel, Akakin, Velio?lu-O?ünç, Tetik, Ozdemir, Sener, Ye?en: "The anti-inflammatory and neuroprotective effects of ghrelin in subarachnoid hemorrhage-induced oxidative brain damage in rats." in: Journal of neurotrauma, Vol. 27, Issue 6, pp. 1143-55, (2010) (PubMed).

  • Target Alle S100B ELISA Kits anzeigen
    S100B (S100 Calcium Binding Protein B (S100B))
    Andere Bezeichnung
    S100B (S100B Produkte)
    Synonyme
    NEF ELISA Kit, S100 ELISA Kit, S100-B ELISA Kit, S100beta ELISA Kit, S100P ELISA Kit, AI850290 ELISA Kit, Bpb ELISA Kit, si:dkey-110p14.2 ELISA Kit, wu:fq18b10 ELISA Kit, zgc:92776 ELISA Kit, S100 calcium binding protein B ELISA Kit, S100 protein, beta polypeptide, neural ELISA Kit, S100 calcium binding protein, beta (neural) ELISA Kit, S100B ELISA Kit, S100b ELISA Kit, s100b ELISA Kit
    UniProt
    P04631
    Pathways
    Regulation of Muscle Cell Differentiation, Positive Regulation of Immune Effector Process, Toll-Like Receptors Cascades, Regulation of long-term Neuronal Synaptic Plasticity, S100 Proteine
Sie sind hier:
Kundenservice