H1N1 IgM Antibody ELISA Kit

Antigen

H1N1 IgM Antibody

Reaktivität
Alternativen

Human

Alternativen: Maus (1)
Applikation
ELISA
Zertifikate ISO 9001:2008
Produktnummer ABIN367612
Menge 96 tests
Preis 711,26 €   Zzgl. Versandkosten €20,00 und MWSt
Lieferung nach
Verfügbarkeit Lieferung in 7 bis 10 Werktagen

Produktbeschreibung

Produktmerkmale This immunoassay kit allows for the in vitro semi-quantitative determination of human H1N1 IgM antibody concentrations in serum, plasma and other biological fluids.
Proben Serum, Plasma
Spezifität This assay recognizes human H1N1 IgM antibody. No significant cross-reactivity or interference was observed.

Anwendungen

Prinzip The microtiter plate provided in this kit has been pre-coated with purified HA antigen. Samples are then added to the appropriate microtiter plate wells and incubated. Then add Horseradish Peroxidase (HRP)-conjugated anti-human IgM to each well and incubate. Finally, a TMB (3,3',5,5' tetramethyl-benzidine) substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. Calculate the valence of H1N1 IgM antibody in the samples.
Protokoll Preparation of Reagents: Bring all reagents to room temperature before use. 1. Wash Buffer If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 500 ml of Wash Buffer. 2. HRP-anti-human IgM Dilute to the working concentration using HRP-anti-human IgM Diluent(1:100), respectively. Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material. Sample Collection and Storage: Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 g. Remove serum and assay immediately or aliquot and store samples at -20° C. Avoid repeated freeze-thaw cycles. Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediately or aliquot and store samples at -20° C. Avoid repeated freeze-thaw cycles. Assay Procedure: Calculation of Results: For calculation the valence of human H1N1 IgM antibody, please dilute the sample from 1:40 using Sample Diluent. Compare the sample well with control. The dilution factor with significant difference color is determined as the final valence. Limitations of the Procedure: The kit should not be used beyond the expiration date on the kit label. Do not mix or substitute reagents with those from other lots or sources. Any variation in operator, pipetting technique, washing technique, incubation time or temperature, and kit age can cause variation in binding. This assay is designed to eliminate interference by soluble receptors, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
Testdurchführung Assay Time: 1-3h
Sample Volume: 50-100ul
Applikationshinweise Detection Wavelength: 450 nm
Bestandteile Reagent Quantity Assay plate 1 Sample Diluent 1 x 20 ml HRP-anti-human IgM Diluent 1 x 10 ml HRP-anti-human IgM 1 x 120µl (1:100) Wash Buffer 1 x 20 ml (25×concentrate) TMB Substrate 1 x 10 ml Stop Solution 1 x 10 ml STORAGE 1. Unopened test kits should be stored at 2-8°C upon receipt and the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit. Refer to the package label for the expiration date. 2. Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above. 3. A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
Benötigtes Material Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm. Pipettes and pipette tips. Deionized or distilled water. Squirt bottle, manifold dispenser, or automated microplate washer.
Lagerung 1. Unopened test kits should be stored at 2-8°C upon receipt and the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit. Refer to the package label for the expiration date. 2. Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above. 3. A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement. Expiration date: six months from the date of manufacture.
Beschränkungen Nur für Forschungszwecke einsetzbar

Alternativen

Alternativen zu Antigen "H1N1 IgM Antibody", Typ "Kits" finden
Reaktivitäten Maus (1)