Telefon:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@antikoerper-online.de

alpha Fetoprotein ELISA Kit

AFP Reaktivität: Human Colorimetric Sandwich ELISA 5-500 ng/mL Serum
Produktnummer ABIN3073418
  • Target Alle alpha Fetoprotein (AFP) ELISA Kits anzeigen
    alpha Fetoprotein (AFP) (alpha-Fetoprotein (AFP))
    Reaktivität
    • 7
    • 5
    • 3
    • 3
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Human
    Nachweismethode
    Colorimetric
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    5-500 ng/mL
    Untere Nachweisgrenze
    5 ng/mL
    Applikation
    ELISA
    Verwendungszweck
    The AFP Enzyme-Linked Immunosorbent Assay (ELISA) Kit provides materials for the quantitative measurement of AFP in serum. This kit is intended for laboratory research use only and is not for use in diagnostic or therapeutic procedures. The concentration of AFP in a given specimen determined with assays from different manufacturers can vary due to differences in assay methods and reagent specificity. The results reported by the laboratory to the physician must include the identity of the AFP assay used. Values obtained with different AFP assays cannot be used interchangeably. Before changing assays, the laboratory must confirm baseline values for patients being serially monitored.
    Proben
    Serum
    Analytische Methode
    Quantitative
    Sensitivität
    0.074 ng/mL
    Bestandteile
    • AFP Calibrator A/Sample Diluent
    • AFP Calibrators B-F (Lyophilized)
    • AFP Controls (Lyophilized)
    • Anti-AFP Antibody Coated Microtitration Strips
    • AFP Assay Buffer
    • AFP Antibody Enzyme Conjugate Ready-To-Use
    • TMB Chromogen Solution
    • Wash Concentrate A
    • Stopping Solution
    Benötigtes Material
    1. Microtitration plate reader capable of absorbance measurement at 450 nm, 405nm and 630 nm.
    2. Microtitration orbital plate shaker.
    3. Microtitration plate washer.
    4. Semi-automated/manual precision pipette to deliver 2-250 μL.
    5. Semi-automated/manual precision pipette to deliver 1-10 μL.
    6. Repeater Pipette.
    7. Vortex mixer.
    8. Deionized water.
    Featured
    Zu unserem meistverkauften AFP ELISA Kit
    Top Product
    Discover our top product AFP ELISA Kit
  • Probenmenge
    25 μL
    Testdauer
    1 h
    Plattentyp
    Pre-coated
    Aufbereitung der Reagenzien
    1. AFP Calibrators B-F and AFP Controls I & II: Tap and reconstitute AFP Calibrator B-F and AFP Controls I & II each with 0.5 mL deionized water. Solubilize, mix well and use after reconstitution.
    2. Wash Solution: Dilute wash concentrate 25-fold with deionized water. The wash solution is stable for one month at room temperature when stored in a tightly sealed bottle.
    3. Microtitration Wells: Select the number of coated wells required for the assay. The remaining unused wells should be placed in the resealable pouch with a desiccant. The pouch must be resealed to protect from moisture.
    Probennahme
    • Serum is the recommended sample type.
    • Sample handling, processing, and storage requirements depend on the brand of blood collection tube29 that you use. Please reference the manufacturer's instructions for guidance. Each laboratory should determine the acceptability of its own blood collection tubes and serum separation products.
    • Samples may be stored at 4 °C if assayed within 24 hours, otherwise samples must be stored at -20 °C or -80 °C to avoid loss of bioactivity and contamination.
    • Avoid assaying lipemic, hemolyzed or icteric samples.
    • Avoid repeated freezing and thawing of samples. Thaw samples no more than 3 times.
    • For shipping, place specimens in leak proof containers in biohazard specimen bags with appropriate specimen identification and test requisition information in the outside pocket of the biohazard specimen bag. Follow DOT and IATA requirements when shipping specimens.
    Testdurchführung

    Allow all samples and reagents to reach room temperature. Mix reagents thoroughly by gentle inversion before use. After reconstitution of reagents, mix thoroughly, avoiding foam. Calibrators, controls and samples should be assayed in duplicate.

    1. Reconstitute AFP Calibrator B-F and AFP Controls I & II each with 0.5 mL deionized water. Solubilize for 10 minutes, Mix well.
    2. Mark the microtitration strips to be used.
    3. Pipet 25 μL of the calibrators, controls and unknown samples to the appropriate wells.
    4. Add 50 μL of the AFP Assay Buffer to each well using a repeater pipette.
    5. Incubate the wells, shaking at 600-800 rpm on an orbital microplate shaker, for 30 mins at room temperature (23 ± 2 °C).
    6. Aspirate and wash each well 5 times with the wash solution (350 μL/well) using an automatic microplate washer.
    7. Add 100 μL of the Antibody-enzyme conjugate ready to use solution to each well using a precision pipette.
    8. Incubate the wells, shaking at 600-800 rpm on an orbital microplate shaker, for 30 mins at room temperature (23 ± 2 °C).
    9. Aspirate and wash each well 5 times with the wash solution (350 μL/well) using an automatic microplate washer.
    10. Add 100 μL of the TMB chromogen solution to each well using a repeater pipette. Avoid exposure to direct sunlight.
    11. Incubate the wells, shaking at 600-800 rpm on an orbital microplate shaker, for 8-12 min at room temperature (23 ± 2 °C). NOTE: Visually monitor the color development to optimize the incubation time.
    12. Add 100 μL of the Stopping solution to each well using a repeater pipette. Read the absorbance of the solution in the wells within 20 minutes, using a microplate reader set to 450 nm. NOTE: Zero calibrator should be programmed as "Blank" while reading the optical density. If instrument has a wavelength correction, set the instrument to dual wavelength measurement at 450 nm with background wavelength correction at 630 nm.

    Ergebnisberechnung

    NOTE: The results in this package insert were calculated by plotting the log optical density (OD) data on the y-axis and log AFP concentration on X-axis using a cubic regression curve-fit. Other data reduction methods may give slightly different results.

    1. Optimum results can be obtained at incubation temperature of (23 ± 2 °C).
    2. Calculate the mean OD for each calibrator, control or diluted sample.
    3. Plot the log of the mean OD readings for each of the Calibrators along the y-axis versus log of the AFP concentrations in ng/mL on the x-axis, using a cubic regression curve fit.
    4. Determine the AFP concentrations of the controls and samples from the calibration curve by matching their mean OD readings with the corresponding AFP concentrations.
    5. Any sample reading higher than the highest calibrator should be appropriately diluted using calibrator A/sample diluent and re-assayed.
    6. Any sample reading lower than the analytical sensitivity should be reported as such.

    Testpräzision
    Reproducibility of the picoPAPP-A ELISA assay was determined using three serum pools for a total of 12 assays. At concentrations between 23.3 and 201.08 ng/mL, the CV's ranged between 4.8 1nd 8.3%.
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Vorsichtsmaßnahmen
    For in vitro diagnostic use. The following precautions should be observed: a) Follow good laboratory practice. b) Use personal protective equipment. Wear lab coats and disposable gloves when handling immunoassay materials. c) Handle and dispose of all reagents and material in compliance with applicable regulations WARNING: Potential Biohazardous Material This reagent may contain some human source material (e.g. serum) or materials used in conjunction with human source materials. Handle all reagents and patient samples at a Biosafety Level 2, as recommended for any potentially infectious human material in the Centers for Disease Control/National Institutes of Health manual "Biosafety in Microbiological and Biomedical Laboratories," 5th Edition, 2007. WARNING: Potential Chemical Hazard Some reagents in this kit contain Pro-Clean 400 as a preservative. Pro-Clean 400 and peroxide in concentrated amounts are irritants to skin and mucous membranes. For further information regarding hazardous substances in the kit, please refer to the MSDS.
    Lagerung
    4 °C
  • Target Alle alpha Fetoprotein (AFP) ELISA Kits anzeigen
    alpha Fetoprotein (AFP) (alpha-Fetoprotein (AFP))
    Andere Bezeichnung
    AFP (AFP Produkte)
    Synonyme
    FETA ELISA Kit, HPAFP ELISA Kit, alpha fetoprotein ELISA Kit, alpha-fetoprotein ELISA Kit, AFP ELISA Kit, Afp ELISA Kit
    Pathways
    C21-Steroid Hormone Metabolic Process
Sie sind hier:
Kundenservice