LTA4H ELISA Kit

LTA4H Reaktivität: Maus Colorimetric Sandwich ELISA 0.156 ng/mL - 10 ng/mL Plasma, Serum, Tissue Homogenate
Produktnummer ABIN1571104
  • Target Alle LTA4H ELISA Kits anzeigen
    LTA4H (Leukotriene A4 Hydrolase (LTA4H))
    Reaktivität
    • 4
    • 2
    • 1
    • 1
    Maus
    Nachweismethode
    Colorimetric
    Methodentyp
    Sandwich ELISA
    Detektionsbereich
    0.156 ng/mL - 10 ng/mL
    Untere Nachweisgrenze
    0.156 ng/mL
    Applikation
    ELISA
    Verwendungszweck
    The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of LTA4H in mouse serum, plasma, tissue homogenates and other biological fluids.
    Proben
    Plasma, Serum, Tissue Homogenate
    Analytische Methode
    Quantitative
    Spezifität
    This assay has high sensitivity and excellent specificity for detection of this index.
    Kreuzreaktivität (Details)
    No significant cross-reactivity or interference between this index and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross- reactivity detection between this index and all the analogues, therefore, cross reaction may still exist.
    Sensitivität
    0.051 ng/mL
    Bestandteile
    • Pre-coated, ready to use 96-well strip plate
    • Standard (freeze dried)
    • Standard Diluent
    • Detection Reagent A
    • Detection Reagent B
    • Assay Diluent A
    • Assay Diluent B
    • TMB
    • Stop Solution
    • Wash Buffer (30X)
    • Plate sealer for 96 wells
    • Instruction manual
    Benötigtes Material
    1. Microplate reader with 450 ± 10nm filter.
    2. Precision single or multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. Deionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Zu unserem meistverkauften LTA4H ELISA Kit
    Top Product
    Discover our top product LTA4H ELISA Kit
  • Probenmenge
    100 μL
    Testdauer
    1 - 4.5 h
    Plattentyp
    Pre-coated
    Protokoll
    1. Prepare all reagents, samples and standards
    2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
    3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
    4. Aspirate and wash 3 times
    5. Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
    6. Aspirate and wash 5 times
    7. Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
    8. Add 50µL Stop Solution. Read at 450nm immediately.
    Testdurchführung

    The microtiter plate provided in this kit has been pre-coated with an antibody specific to the index. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific to the index. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain the index, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of the index in the samples is then determined by comparing the O.D. of the samples to the standard curve.

    Testpräzision
    • Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
    • Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
    • CV(%) = SD/meanX100
    • Intra-assay: CV<10%
    • Inter-assay: CV<12%
    Beschränkungen
    Nur für Forschungszwecke einsetzbar
  • Vorsichtsmaßnahmen
    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
    Handhabung
    The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
    Lagerung
    4 °C,-20 °C
    Informationen zur Lagerung
    The Assay Plate, Standard, Detection Reagent A and Detection Reagent B should be stored at -20°C upon being received. After receiving the kit , Substrate should be always stored at 4°C.Other reagents are kept according to the labels on vials. But for long term storage, please keep the whole kit at -20°C. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. The test kit may be used throughout the expiration date of the kit (six months from the date of manufacture). Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
    Haltbarkeit
    12 months
  • Target Alle LTA4H ELISA Kits anzeigen
    LTA4H (Leukotriene A4 Hydrolase (LTA4H))
    Andere Bezeichnung
    LTA4H (LTA4H Produkte)
    Synonyme
    LTA4H ELISA Kit, zgc:85809 ELISA Kit, MGC78867 ELISA Kit, lta4h ELISA Kit, MGC69197 ELISA Kit, LOC732953 ELISA Kit, DDBDRAFT_0191291 ELISA Kit, DDBDRAFT_0216768 ELISA Kit, DDB_0191291 ELISA Kit, DDB_0216768 ELISA Kit, AmpT ELISA Kit, leukotriene A4 hydrolase ELISA Kit, leukotriene A4 hydrolase L homeolog ELISA Kit, Leukotriene A4 hydrolase ELISA Kit, LTA4H ELISA Kit, lta4h ELISA Kit, lta4h.L ELISA Kit, LOC732953 ELISA Kit, Shew185_1367 ELISA Kit, Sbal195_1406 ELISA Kit, XfasM23_0741 ELISA Kit, Sbal223_2977 ELISA Kit, lkhA ELISA Kit, Lta4h ELISA Kit
    Hintergrund
    Alternative name: LTA4 Hydrolase
    Gen-ID
    16993
    UniProt
    P24527